Kenmore Dryer F-31 and F:31 Codes (Oasis and Elite, Low Supply Leg)

F-31 and F:31 on the Whirlpool-built Oasis and Elite dryers mean the second leg of the 240-volt supply has dropped below roughly 30 volts. The drum can still turn on the remaining leg while heating has nothing to draw on.

What F-31 / F:31 (110 / Whirlpool-built Oasis and Elite) Means

F-31 and F:31 on the Whirlpool-built Oasis and Elite dryers mean the second leg of the 240-volt supply has dropped below roughly 30 volts. The drum can still turn on the remaining leg while heating has nothing to draw on.

Common Causes of F-31 / F:31 (110 / Whirlpool-built Oasis and Elite)

  • One side of a double-pole breaker tripped or failed internally
  • A loose or burnt connection at the dryer terminal block
  • A damaged supply cord on one leg

🔧 One Safe Check You Can Try

Reset the dryer's house breaker properly — fully off, then on — because a double-pole breaker can trip on one side while the handle still looks engaged.

⚠ Why You Shouldn't Go Further Than That

  • A 240-volt terminal block that has been arcing needs an electrician, not a screwdriver and optimism.
  • Burnt terminals are replaced rather than retightened, because the damage is already done to the metal.
  • No dryer component will restore a supply leg that is missing before the machine.

Opening a panel to inspect or repair something yourself doesn't automatically cancel your manufacturer's warranty — but it can risk accidental damage, and some manufacturers do have specific service conditions. Check your product's warranty terms, or ask us, before deciding.

Other Dryer Error Codes

Related Guides

Still Seeing F-31 / F:31 (110 / Whirlpool-built Oasis and Elite)?

Book a trained technician and get it diagnosed correctly the first time — no guesswork, no repeat visits.

Book Repair for F-31 / F:31 (110 / Whirlpool-built Oasis and Elite)

Same-day & next-day appointments · No hidden fees · Technicians trained on these appliances

1Service Details
2Date & Time
3Contact Info

or call (844) 621-1345 now

FAQ

F-31 / F:31 (110 / Whirlpool-built Oasis and Elite) FAQ

That is the classic presentation, because the motor runs on one leg and the heater needs both.

A failing protector or a worn outlet can certainly interrupt one leg, and both are worth checking before the dryer is opened.