Kenmore Refrigerator F3 and r3 Codes (111-Prefix, Defrost Heaters)

F3 and r3 on 111-prefix Kenmore bottom-freezer refrigerators report a defrost heater as failed — F3 for the freezer evaporator, r3 for the fresh-food one. Without the heater, frost accumulates on the coil until airflow stops.

What F3 / r3 (111-prefix) Means

F3 and r3 on 111-prefix Kenmore bottom-freezer refrigerators report a defrost heater as failed — F3 for the freezer evaporator, r3 for the fresh-food one. Without the heater, frost accumulates on the coil until airflow stops.

Common Causes of F3 / r3 (111-prefix)

  • A defrost heater element gone open circuit
  • Broken or corroded wiring at the heater terminals
  • A defrost circuit fault on the control board

🔧 One Safe Check You Can Try

Note how quickly frost is returning after any manual defrost; a compartment that ices up again within days tells a technician the heater is genuinely dead rather than intermittently working.

⚠ Why You Shouldn't Go Further Than That

  • Unplug the refrigerator and let ice melt before the evaporator cover comes away — the heater sits against the coil at line voltage.
  • Chipping ice off a coil to get at the heater bends fins and punctures tubing with alarming ease.
  • Fitting a heater onto corroded terminals repeats the failure within a season.

Opening a panel to inspect or repair something yourself doesn't automatically cancel your manufacturer's warranty — but it can risk accidental damage, and some manufacturers do have specific service conditions. Check your product's warranty terms, or ask us, before deciding.

Other Refrigerator Error Codes

Related Guides

Still Seeing F3 / r3 (111-prefix)?

Book a trained technician and get it diagnosed correctly the first time — no guesswork, no repeat visits.

Book Repair for F3 / r3 (111-prefix)

Same-day & next-day appointments · No hidden fees · Technicians trained on these appliances

1Service Details
2Date & Time
3Contact Info

or call (844) 621-1345 now

FAQ

F3 / r3 (111-prefix) FAQ

Warm air at a distance is safer than any heat gun or hot water, but the appliance should be unplugged and the melt water managed.

This platform cools each compartment with its own evaporator, so each one needs its own defrost heater.

Need a repair? We're ready to help. Call Now
Call Us Schedule